Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1528847

RESUMO

This study aimed to compare the subgingival microbiota of subjects with and without breast cancer (BC). Patients with BC (Group 1; n= 50) and without BC (Group 2; n=50) with periodontitis (A) and without periodontitis (B). The study was conducted in two phases (P1 and P2). One biofilm sample was collected from each subject and analyzed by DNA-DNA Hybridization (Checkerboard DNA-DNA). The relative abundance of the subgingival microbiota differed between the Case and Control groups. However, some species were higher in patients in the Case than in Control subjects and differed between the groups in both phases. Composition of the subgingival microbial community according to the Socransky complex was related to periodontal disease, followed by clinical attachment of level (CAL ≥4mm), age, and tooth loss, which were found to be abundant in Cases when compared with controls. Patients with Tumor Grade II and III had a higher prevalence of tooth loss and CAL≥4mm. It was concluded that in individuals with BC, the sub-gingival microbiota exhibited atypical changes, but they developed periodontal disease.


El objetivo de este estudio fue comparar la microbiota subgingival de sujetos con y sin cáncer de mama (CM). Pacientes con CM (Grupo 1; n= 50) y sin CM (Grupo 2; n=50) con periodontitis (A) y sin periodontitis (B). El estudio se realizó en das fases (P1 y P2). Se recogió una muestra de biopelícula de cada sujeto y se analizó mediante hibridación ADN-ADN (tablero de ajedrez ADN-ADN). La abundancia relativa de la microbiota subgingival difirió entre los grupos de Caso y Control. Sin embargo, algunas especies fueron más altas en los pacientes del Caso que en los sujetos del Control y difirieron entre los grupos en ambas fases. La composición de la comunidad microbiana subgingival según el complejo de Socransky se relacionó con la enfermedad periodontal, seguida por el nivel de inserción clínica (CAL≥4mm), la edad y la pérdida de dientes, que se mostró abundante en los casos en comparación con los controles. Los pacientes con Tumor Grado II y III tuvieron mayor prevalencia de pérdida dental y CAL≥4mm. Se concluyó que en individuos con CM la microbiota subgingival presentó cambios atípicos, pero sin embargo, desarrollaron enfermedad periodontal.

2.
Int. j. odontostomatol. (Print) ; 17(3): 356-371, sept. 2023. ilus, tab, graf
Artigo em Inglês | LILACS | ID: biblio-1514380

RESUMO

The present study aimed to review the literature on the main complications of antineoplastic therapies and the degree of knowledge of dental surgeons about these complications. A bibliographic search was conducted in the main health databases PUBMED (www.pubmed.gov) and Scholar Google (www.scholar.google.com.br), in which studies published from 1987 to 2023 were collected. Laboratory studies, case reports, systematic and literature reviews, which were developed in living individuals, about the main neoplastic genes and their relationship with the cells of individuals affected by neoplasms in the head and neck region, and studies on the care with this group of patients, were included. Therefore, articles that did not deal with neoplasm and the main complications of antineoplastic therapies were excluded. Neoplasm is a clonal disorder, caused by mutations, resulting from changes in the genetic structure of cells. Each healthy cell has instructions on how to grow and divi de. In the presence of any error in these instructions (mutation), it can result in a diseased cell that, when proliferating, may cause a tumor. Countless knowledge has been accumulated over the years on the main characteristics of neoplasms, whether they are cancer cell biology, carcinogenesis mechanism, neoplasms of the maxillofacial system and sequels of antineoplastic treatments. In this context, methods have been developed that offer a better quality of life for patients diagnosed with this pathology, as well as preventive vaccine models that may, in the not too distant future, contribute to this goal to be successfully achieved.


El presente estudio tuvo como objetivo revisar la literatura sobre las principales complicaciones de las terapias antineoplásicas y el grado de conocimiento de los odontólogos sobre este abordaje. Se realizó una búsqueda bibliográfica en las principales bases de datos de salud PUBMED (www.pubmed.gov) y Scholar Google (www.scholar.google.com.br), en la que se recopilaron estudios publicados entre 1987 y 2023. Fueron incluidos estudios de laboratorio, relatos de casos, revisiones de la literatura y revisiones sistemáticas, desarrolladas en individuos vivos, que incluyeran los principales genes neoplásicos y su relación con las células de individuos afectados por neoplasias en la cabeza y el cuello. También, se tuvieron en cuenta estudios relacionados con la atención a este grupo de pacientes. La neoplasia es un trastorno clonal, causado por mutaciones, como resultado de cambios en la estructura genética de las células. Cada célula sana tiene instrucciones sobre cómo crecer y dividirse. En presencia de cualquier error en estas instrucciones (mutación), puede provocar una célula alterada que, al proliferar, puede causar un tumor. Se han acumulado innumerables conocimientos a lo largo de los años sobre las principales características de las neoplasias, ya sea sobre biología de células cancerosas, el mecanismo de la carcinogénesis, la neoplasias del sistema maxilofacial y las diferentes secuelas de tratamientos antineoplásicos. En este contexto, se han desarrollado métodos que ofrecen una mejor calidad de vida para los pacientes diagnosticados con esta patología, así como modelos de vacunas preventivas que, en un futuro no muy lejano, pueden contribuir a alcanzar este objetivo con éxito.


Assuntos
Humanos , Assistência Odontológica , Genes Neoplásicos/genética , Neoplasias de Cabeça e Pescoço/genética
3.
Braz. dent. sci ; 26(2): 1-10, 2023. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1436570

RESUMO

The maxillary bone restriction can limit the implants position to support a full-arch prosthesis. Objective:Therefore, this study evaluated the biomechanical behavior of a full-arch prosthesis supported by six implants in different configurations: group A (implants inserted in the region of canines, first premolars and second molars), group B (implants inserted in the region of first premolar, first molar and second molar) and group C (implants in second premolar, first premolar and second molar). Material and Methods: The models were analyzed by the finite element method validated by strain gauge. Three types of loads were applied: in the central incisors, first premolars and second molars, obtaining results of von-Mises stress peaks and microstrain. All registered results reported higher stress concentration in the prosthesis of all groups, with group C presenting higher values in all structures when compared to A and B groups. The highest mean microstrain was also observed in group C (288.8 ± 225.2 µÎµ/µÎµ), however, there was no statistically significant difference between the evaluated groups. In both groups, regardless of the magnitude and direction of the load, the maximum von-Mises stresses recorded for implants and prosthesis displacements were lower in group A. Conclusion: It was concluded that an equidistant distribution of implants favors biomechanical behavior of full-arch prostheses supported by implants; and the placement of posterior implants seems to be a viable alternative to rehabilitate totally edentulous individuals. (AU)


A limitação óssea maxilar totais pode limitar o posicionamento dos implantes para suportar uma prótese de arco total. Objetivo: Sendo assim, este estudo avaliou o comportamento biomecânico de uma prótese de arco total suportada por seis implantes em diferentes configurações: grupo A (implantes inseridos na região de caninos, primeiros pré-molares e segundos molares), grupo B (implantes inseridos na região de primeiro pré-molar, primeiro molar e segundo molar) e grupo C (implantes em segundo pré-molar, primeiro pré-molar e segundo molar). Materiais e métodos: Os modelos foram analisados pelo método de elementos finitos validados por extensometria. Foram aplicados três tipos de cargas: nos incisivos centrais, primeiros pré-molares e nos segundos molares, obtendo resultados de picos de tensão de von-Mises e microdeformação. Todos os resultados registrados mostraram maior concentração de tensão na prótese de todos os grupos, sendo que o grupo C apresentou maiores valores em todas as estruturas quando comparado com os grupos A e B. A maior média de microdeformação também foi observada no grupo C (288,8 ± 225,2 µÎµ/µÎµ), no entanto, não houve diferença estatisticamente significativa entre os grupos avaliados. Em todos os grupos, independentemente da magnitude e direção da carga, as tensões máximas de von-Mises registradas para os implantes e deslocamentos de próteses foram menores no grupo A. Conclusão: Concluiu-se que a distribuição de implantes de forma equidistante favorece o desempenho biomecânico das próteses de arco total suportada por implantes; e o posicionamento de implantes posteriores parece ser uma alternativa viável para reabilitar indivíduos densdentados totais. (AU)


Assuntos
Fenômenos Biomecânicos , Implantes Dentários , Prótese Dentária , Análise de Elementos Finitos , Maxila
4.
Materials (Basel) ; 15(22)2022 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-36431619

RESUMO

The present study aimed to evaluate the biomechanical behavior of PEEK abutments with different heights on single titanium implants. To investigate the implant surface, different tests (scanning electron microscopy, energy-dispersive X-ray, and X-ray diffraction) were adopted. Herein, 20 implants received the 4.5 × 4.0 mm PEEK short abutment (SA) and 20 received the 4.5 × 5.5 mm PEEK long abutment (LA). The abutments were installed using dual-cure resin cement. To determine the fatigue test, two specimens from each group were submitted to the single load fracture test. For this, the samples were submitted to a compressive load of (0.5 mm/min; 30°) in a universal testing machine. For the fatigue test, the samples received 2,000,000 cycles (2 Hz; 30°). The number of cycles and the load test was analyzed by the reliability software SPSS statistics using Kaplan-Meier and Mantel-Cox tests (log-rank) (p < 0.05). The maximum load showed no statistically significant differences (p = 0.189) for the SA group (64.1 kgf) and the LA group (56.5 kgf). The study groups were statistically different regarding the number of cycles (p = 0.022) and fracture strength (p = 0.001). PEEK abutments can be indicated with caution for implant-supported rehabilitation and may be suitable as temporary rehabilitation.

5.
Materials (Basel) ; 15(18)2022 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-36143553

RESUMO

This study aimed to evaluate the biomechanical behavior of Morse taper implants using different abutments (CMN abutment [(CMN Group] and miniconical abutments [MC Group]), indicated to support a screw-retained 3-unit fixed partial denture. For the in vitro test, polyurethane blocks were fabricated for both groups (n = 10) and received three implants in the "offset" configuration and their respective abutments (CMN or MC) with a 3-unit fixed partial denture. Four strain gauges were bonded to the surface of each block. For the finite element analysis, 3D models of both groups were created and exported to the analysis software to perform static structural analysis. All structures were considered homogeneous, isotropic, and elastic. The contacts were considered non-linear with a friction coefficient of 0.3 between metallic structures and considered bonded between the implant and substrate. An axial load of 300 N was applied in three points (A, B, and C) for both methods. The microstrain and the maximum principal stress were considered as analysis criteria. The obtained data were submitted to the Mann-Whitney, Kruskal-Wallis, and Dunn's multiple comparison test (α = 5%). The results obtained by strain gauge showed no statistical difference (p = 0.879) between the CMN (645.3 ± 309.2 µÎµ) and MC (639.3 ± 278.8 µÎµ) and allowed the validation of computational models with a difference of 6.3% and 6.4% for the microstrains in the CMN and MC groups, respectively. Similarly, the results presented by the computational models showed no statistical difference (p = 0.932) for the CMN (605.1 ± 358.6 µÎµ) and MC (598.7 ± 357.9 µÎµ) groups. The study concluded that under favorable conditions the use of CMN or MP abutments to support a fixed partial denture can be indicated.

6.
Materials (Basel) ; 15(15)2022 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-35955276

RESUMO

This study aimed to evaluate the influence of thermomechanical cycling (TMC) and type of abutment on the misfit and compressive strength of the implant−abutment interface. Forty 3.75-mm external hexagon implants with 25° angled abutments were divided into four groups (N = 10). Group A: overcast plus TMC; Group B: overcast without TMC; Group C: completely cast plus TMC; Group D: completely cast without TMC. Abutments were fixed to the implants with 32-Ncm torque, and groups A and C specimens were cyclically loaded at 80 N with 2 Hz for 1 million cycles. The misfit on the implant−abutment interface was evaluated by optical microscope (100×) and the compressive strength test was performed in a universal test machine. For statistical analysis, a two-way ANOVA and post hoc Tukey test were used. There was no difference in misfit presented by all the abutments in the absence of TMC (p > 0.05). When TMC was performed, the completely cast abutments showed greater misfit than overcast ones (p = 0.001). Regarding compressive strength, irrespective of TMC performed, the overcast abutments showed higher compressive strength values than completely cast abutments (p = 0.003). Moreover, disregarding the type of abutment used, the absence of TMC provided higher compressive strength values (p < 0.001). It was concluded that thermomechanical cyclic loading aggravated the misfit, especially in completely cast abutments, regardless of material or fabrication technique, and reduced the compressive strength of the two types of abutments tested.

7.
Dent J (Basel) ; 10(8)2022 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-36005243

RESUMO

This study aimed to evaluate the use of bioengineering tools, finite element analysis, strain gauge analysis, photoelastic analysis, and digital image correlation, in computational studies with greater validity and reproducibility. A bibliographic search was performed in the main health databases PUBMED and Scholar Google, in which different studies, among them, laboratory studies, case reports, systematic reviews, and literature reviews, which were developed in living individuals, were included. Therefore, articles that did not deal with the use of finite element analysis, strain gauge analysis, photoelastic analysis, and digital image correlation were excluded, as well as their use in computational studies with greater validity and reproducibility. According to the methodological analysis, it is observed that the average publication of articles in the Pubmed database was 2.03 and with a standard deviation of 1.89. While in Google Scholar, the average was 0.78 and the standard deviation was 0.90. Thus, it is possible to verify that there was a significant variation in the number of articles in the two databases. Modern dentistry finds in finite element analysis, strain gauge, photoelastic and digital image correlation a way to analyze the biomechanical behavior in dental materials to obtain results that assist to obtain rehabilitations with favorable prognosis and patient satisfaction.

8.
Dent J (Basel) ; 10(1)2022 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-35049610

RESUMO

This study evaluated the influence of distal implants angulation and framework material in the stress concentration of an All-on-4 full-arch prosthesis. A full-arch implant-supported prosthesis 3D model was created with different distal implant angulations and cantilever arms (30° with 10-mm cantilever; 45° with 10-mm cantilever and 45° with 6-mm cantilever) and framework materials (Cobalt-chrome [CoCr alloy], Yttria-stabilized tetragonal zirconia polycrystal [Y-TZP] and polyetheretherketone [PEEK]). Each solid was imported to computer-aided engineering software, and tetrahedral elements formed the mesh. Material properties were assigned to each solid with isotropic and homogeneous behavior. The contacts were considered bonded. A vertical load of 200 N was applied in the distal region of the cantilever arm, and stress was evaluated in Von Misses (σVM) for prosthesis components and the Maximum (σMAX) and Minimum (σMIN) Principal Stresses for the bone. Distal implants angled in 45° with a 10-mm cantilever arm showed the highest stress concentration for all structures with higher stress magnitudes when the PEEK framework was considered. However, distal implants angled in 45° with a 6-mm cantilever arm showed promising mechanical responses with the lowest stress peaks. For the All-on-4 concept, a 45° distal implants angulation is only beneficial if it is possible to reduce the cantilever's length; otherwise, the use of 30° should be considered. Comparing with PEEK, the YTZP and CoCr concentrated stress in the framework structure, reducing the stress in the prosthetic screw.

9.
Comput Methods Biomech Biomed Engin ; 25(3): 239-246, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34559574

RESUMO

This study aimed to evaluate the biomechanical behavior, stress distributions and bone microstrain of fixed partial dentures (FPD) with ceramic abutments supported on monotype zirconia implants, titanium implants and two-piece zirconia implants, using finite element analysis. A three-dimensional model of the jaw was simulated containing 1.0 mm thick cortical bone and cancellous bone tissue. A FPD and implant models (4.1 x 10 mm) were modeled containing a cement-retained implant abutment. These models were replicated in three groups with similar geometries: Titanium Implant and Zirconia Abutment (Ti-Zr); Zirconia Implant and Zirconia Abutment (Zr-Zr) and Monotype Zirconia Implant (Zr-S). An axial load of 300 N was applied to the center of the first premolar. The microstrain (µÎµ) and the Von-Mises stress (MPa) were assumed as failures criteria. For the three groups, a higher stress concentration was observed in the region of FPD connectors. The Ti-Zr group showed a higher stress concentration in the prosthesis and implant when compared to the other groups. However, the smaller elastic modulus of the titanium implant, in relation to the zirconia, provided a lower stress in the abutment and in the prosthetic screw. The monotype implant system allowed a more homogeneous stress distribution and its strain were predominantly located in the cervical region of the peri-implant bone tissue. Monotype or two-piece zirconia implants can be used for rehabilitation with FPD. However, the absence of separation between implant and abutment in the monotype system avoids the stress concentration in the prosthetic screw and reduced the peri-implant bone strain.


Assuntos
Implantes Dentários , Dente Suporte , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Prótese Parcial Fixa , Análise de Elementos Finitos , Estresse Mecânico , Titânio , Zircônio
10.
Braz. dent. sci ; 25(4): 1-9, 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1410540

RESUMO

Aim: To describe through a clinical case report the surgical sequence of rehabilitation with 3D-printed implants associated with maxillary sinus floor lift with synthetic regenerative materials, including biphasic bioceramic. Case Report: Patient had an agenesis of the upper left premolars (#12 and #13), a vertical bone deficiency caused by maxillary sinus' pneumatization, and a horizontal alveolar resorption around the missing teeth area. During the surgical procedures, incisions, detachment, and osteotomy were performed in the lateral region of the maxillary sinus. The sinus membrane was detached and lifted 10 mm. Then, a thick poly(dioxanone)-based synthetic resorbable membrane (Plenum) was inserted and adapted inside the sinus to protect the sinus membrane. After the osteotomies with sub-instrumentation, 3D-printed implants (Plenum) were installed in the #12 area (3.5mm x 11.5 mm; 30N) and #13 area (4.0mm x 10mm; 20N). The maxillary sinus was entirely filled with a biphasic bioceramic, HA/ß-TCP (70:30) 500-1000 µm (Plenum) and covered by the same synthetic resorbable membrane. Connective tissue graft from the palatal area was positioned internally to the flap and stabilized with sutures to improve the vestibular tissue architecture. The entire surgical wound was sutured, and the tissues stabilized. No complications occurred in the postoperative period. Conclusion: The use of synthetic regenerative memberane and 3D-printed implants seems to be a promising option in areas of deficient bone remnants (AU)


Objetivo: Descrever por meio de um relato de caso clínico a sequência cirúrgica de reabilitação com implantes obtidos por impressão 3D associados à elevação do assoalho do seio maxilar com materiais regenerativos sintéticos, incluindo uma biocerâmica bifásica. Relato de Caso: Paciente apresentava agenesia dos pré-molares superiores esquerdos (24 e 25), deficiência óssea vertical causada pela pneumatização do seio maxilar e reabsorção alveolar horizontal ao redor da área dos dentes ausentes. Durante os procedimentos cirúrgicos foram realizados incisões, descolamento e osteotomia na região lateral do seio maxilar. A membrana sinusal foi descolada e elevada 10 mm. Em seguida, uma membrana reabsorvível sintética à base de poli(dioxanona) espessa (Plenum) foi inserida e adaptada dentro do seio para proteger a membrana do seio. Após as osteotomias com subinstrumentação, implantes impressos em 3D (Plenum) foram instalados na área do 24 (3,5mm x 11,5mm; 30N) e na área do 25 (4,0mm x 10mm; 20N). O seio maxilar foi inteiramente preenchido com biocerâmica bifásica, HA/ß-TCP (70:30)500-1000 µm (Plenum) e recoberto pela mesma membrana sintética reabsorvível. O tecido conjuntivo da região palatina foi posicionado internamente ao retalho e estabilizado com suturas para melhorar a arquitetura do tecido vestibular. Toda a ferida cirúrgica foi suturada e os tecidos estabilizados. Não ocorreram complicações no pós-operatório. Conclusão:A utilização de biomateriais regenerativos sintéticos e implantes impressos parece ser uma opção promissora em áreas de remanescentes ósseos deficientes.(AU)


Assuntos
Humanos , Masculino , Adulto , Implantes Dentários , Transplante de Tecidos , Levantamento do Assoalho do Seio Maxilar , Impressão Tridimensional , Seio Maxilar
11.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385835

RESUMO

ABSTRACT: To evaluate the stresses generated in upper premolars rehabilitated with ceramic fragments (table-top) of lithium disilicate on the occlusal surface. An upper premolar was modeled following its anatomical references using computer aided design software (Rhinoceros version 5.0 SR8, USA). The dental tissues were individually designed containing enamel, dentin and periodontal ligament. The main anatomical points were used as parameters for model creation. Ceramic fragments were modeled varying their maximum thicknesses as: 0.5 mm, 1.0 mm and 1.5 mm. Solid geometries were exported to the analysis software (ANSYS 17.2, USA) in STEP format. The materials were considered isotropic, homogeneous and linear, and the values of the elastic modulus of the materials and structures were used to perform a static structural mechanical analysis. The set was submitted to 200 N load. The system fixation was defined on the basis of the three- dimensional model, and the results were obtained in MPa according to the failure criteria of the analyzed materials (tensile stress). Occlusal restoration was not detrimental to mechanical behavior. Stress distribution in the internal region of the restoration was similar between the groups. Thicker fragments presented a lower concentration of tensile stress, therefore suggesting better prognosis in attenuating tensile stresses in the tooth region. More conservative occlusal ceramic fragments presented worse prognosis. However, all evaluated thickness for table-tops support the occlusal rehabilitation of upper premolars when submitted to 200 N loading.


RESUMEN: El objetivo fue evaluar las tensiones generadas en los premolares superiores rehabilitados con fragmentos cerámicos (tablero) de disilicato de litio en la superficie oclusal. Se modeló un premolar superior siguiendo sus referencias anatómicas utilizando un software de diseño asistido por computadora (Rhinoceros versión 5.0 SR8, EE. UU.). Los tejidos dentales se moldearon individualmente conteniendo esmalte, dentina y ligamento periodontal. Los principales puntos anatómicos se utilizaron como parámetros para la creación del modelo. Los fragmentos cerámicos se modelaron variando sus espesores máximos como: 0,5 mm, 1,0 mm y 1,5 mm. Las geometrías sólidas se exportaron al software de análisis (ANSYS 17.2, EE. UU.) En formato STEP. Los materiales se consideraron isotrópicos, homogéneos y lineales, y los valores del módulo elástico de los materiales y estructuras se utilizaron para realizar un análisis mecánico estructural estático. El conjunto se sometió a una carga de 200 N. La fijación del sistema se definió a partir del modelo tridimensional, y los resultados se obtuvieron en MPa según los criterios de falla de los materiales analizados (tensión de tracción). La restauración oclusal no perjudica el comportamiento mecánico. La distribución de la tensión en la región interna de la restauración es similar entre los grupos. Los fragmentos más gruesos presentaron una menor concentración de tensión de tracción, lo que sugiere un mejor pronóstico en la atenuación de las tensiones de tracción en la región dentaria. Los fragmentos cerámicos oclusales más conservadores presentaron peor pronóstico. Sin embargo, todos los espesores evaluados para tableros de mesa en disilicato de litio apoyan la rehabilitación oclusal de los premolares superiores cuando se someten a una carga de 200 N.

12.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385780

RESUMO

ABSTRACT: The present study aims to describe through a literature review, the main types of noble and non-noble alloys in dentistry looking to identify the adhesion mechanisms, compositions and mechanical properties, and its applicability as a rehabilitation resource nowadays. A bibliographic search was conducted in the main health databases PUBMED (www.pubmed.gov) and Scholar Google (www.scholar.google.com.br), in which studies published from 1971 to 2021 were collected. Laboratory studies, case reports, systematic and literature reviews, which were developed in living individuals. Articles that did not deal with metal alloys and its use in dentistry were excluded. Through the review, it was possible to ver ify that all works presented the metal alloys and their main properties, indicating that they are divided into three main types: hi gh noble alloys, noble alloys and base metal alloys differing in their levels of constituent noble metals. Several alloys and meta ls are available for the dental market each presenting advantages and disadvantages, mainly based on its specific composition.Continuous research and development are resulting in the production of new technologies and products, giving dental surgeons even more options in the design and manufacture of restorations using metal alloys and understanding that these resources will still be viable alternatives in oral rehabilitations. However, further studies on metal alloys are needed to better understand this subject.


RESUMEN: El presente trabajo tuvo como objetivo describir a través de una revisión de la literatura, los principales tipos de aleaciones nobles y no nobles utilizados en odontología buscando identificar los mecanismos de adhesión, composiciones y propiedades mecánicas, así como reflejar su aplicabilidad como recurso rehabilitador en la actualidad. Realizamos una búsqueda bibliográfica em las principales bases de datos de salud PUBMED (www.pubmed.gov) y Scholar Google (www.scholar.google.com.br), en la que se recopilaron estudios publicados desde 1971 hasta 2021. Estudios de laboratorio, informes de casos, revisiones sistemáticas y bibliográficas, que se desarrollaron en individuos vivos. Sin embargo, se excluyeron los artículos que no trataban sobre aleaciones metálicas y su uso en odontología. Se pudo observar que todos los trabajos presentaban las aleaciones metálicas y sus principales propiedades indicando que se estas dividen en tres tipos principales: aleaciones altamente nobles, aleaciones nobles y aleaciones de metales base que difierenen sus niveles de metales nobles constituyentes. Hay varias aleaciones y metales disponibles para el mercado dental, cada uno presenta ventajas y desventajas, principalmente en función de su composición específica. La investigación y el desarrollo continuo están dando como resultado la producción de nuevas tecnologías y productos, brindando a los cirujanos dentistas aún más opciones en el diseño y fabricación de las restauraciones, utilizando aleaciones metálicas y, permite concluir que estos recursos seguirán siendo alternativas viables en los tratamientos de rehabilitación. Sin embargo, se necesitan más estudios sobre el tema abordado en el trabajo, para una comprensión más profunda del tema.

13.
J Clin Exp Dent ; 13(5): e505-e510, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33981399

RESUMO

BACKGROUND: Nylon is a polymer that its use to reinforce dental resins has shown positive results such as increased flexural strength. The aim of this study was to evaluate the bond strength between dental resins and a nylon reinforcement. MATERIAL AND METHODS: Forty cylindrical nylon blocks with 13 x 23 mm with 0.5% by volume of silica and 40 without were made. Half of the samples of each nylon composition were sandblasted with aluminum oxide (50µm) for 3 s (2.8 bar pressure, distance: 20 mm, incidence angle: 90o). On the nylon blocks, cylinders of chemically activated acrylic resin and indirect composite resin were made, with a bonding area of 6,28 mm2. Eight different groups were obtained according to the material used and the surface treatment (n = 10): Acrylic Resin + Nylon; GAS: Acrylic Resin + Nylon with Silica; GAT: Acrylic Resin + Nylon (Al2O3); GAST: Acrylic Resin + Nylon with Silica (Al2O3); GC: Composite Resin + Nylon; GCS: Composite Resin + Nylon with Silica; GCT: Composite Resin + Nylon (Al2O3); GCST: Composite Resin + Nylon with Silica (Al2O3). The shear test was carried out. The Student's and the Kruskal-Wallis test was adopted. RESULTS: There was no statistically difference in the bond strength for nylon with silica for the acrylic resin group. For the composite groups, nylon with silica did not present a statistically difference without surface treatment (p = 0.10) and with surface treatment the bond strength decreased (p = 0.000). The GCT showed a higher bond strength (0.89 MPa). The surface treatment improved the bond strength for the both groups. CONCLUSIONS: The presence of silica in the nylon composition did not influence the bond strength between materials evaluated. However, the surface treatment with aluminum oxide proved to be favorable for this adhesion. Key words:Nylons - Resins, Synthetic - Structures Strengthening - Dental Research.

14.
Sâo José dos Campos; s.n; 20210000. 129 p. il, graf, Tab.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1358945

RESUMO

O objetivo do presente estudo foi avaliar o comportamento biomecânico de diferentes pilares (pilar CMN [Grupo CMN] e minipilares [Grupo MP]) reabilitados com uma prótese múltipla parafusada de três elementos. Para os ensaios laboratoriais foram confecionados blocos em poliuretano para os grupos avaliados (n = 10). Cada bloco recebeu três implantes na configuração "off set", seus respectivos pilares (CMN ou minipilar) e uma prótese múltipla de três elementos. Foram colados quatro extensômetros na superfície de cada bloco tangenciando cada implante para a realização dos ensaios. Para análises pelo método de elementos finitos, os modelos tridimensionais dos dois grupos foram exportados para o software Ansys a fim de realizar uma análise estática estrutural. Todas as estruturas foram consideradas homogêneas, isotrópicas e elásticas. Os contatos entre as estruturas dos modelos tridimensionais foram considerados não lineares com coeficiente de atrito de 0,3 entre as estruturas metálicas e considerada colada entre o implante e o substrato. Foi aplicada uma carga axial de 300N sobre cada um dos 3 implantes (pontos A, B e C) para ambas metodologias. A microdeformação e a tensão máxima principal foram adotadas como critérios de falha. Os dados obtidos nas duas metodologias foram submetidos aos testes de Mann-Whitney, Kruskal-Wallis e ao teste de comparação múltipla de Dunn. Os resultados obtidos pela extensometria não apresentaram diferença estatística (p = 0,879) entre os grupos CMN (645,3 ± 309,2 µÎµ) e MP (639,3 ± 278,8 µÎµ), e ainda permitiu a validação dos modelos teóricos com uma diferença de 6,3 e 6,4% para as microdeformações nos grupos CMN e MP, respectivamente. De forma semelhante, os resultados apresentados pelos modelos teóricos na apresentaram diferença estatística (p = 0,932) para os grupos CMN (605,1 ± 358,6 µÎµ) e MP (598,7 ± 357,9 µÎµ). O estudo concluiu que a utilização de abutments CMN suportando uma prótese múltipla apresentou comportamento biomecânico compatível aos minipilares, sem que causassem uma deformação periférica deletéria (3.000 µÎµ).


The aim of this work was to evaluate the biomechanical behavior of Morse taper implants using different abutments (CMN abutment [CMN Group] and miniconical abutments [MC Group]), indicated to support a screw-retained 3-unit fixed partial denture. For the in vitro test, polyurethane blocks were made for both groups (n=10) and received three implants in the "off set" configuration and their respective abutments (CMN or MC) with a 3-unit fixed partial prosthesis. Four strain gauges were bonded to the surface of each block. For the finite element analysis, 3-D models of both groups were created and exported to the analysis software to perform a static structural analysis. All structures were considered homogeneous, isotropic and elastic. The contacts were considered non-linear with a friction coefficient of 0.3 between metallic structures and considered bonded between the implant and substrate. An axial load of 300N was applied in three points (A, B and C) for both methods. The microstrain and the maximum principal stress were considered as analysis criteria. The data obtained were submitted to the Mann-Whitney, Kruskal- Wallis tests and Dunn's multiple comparison test (α = 5%). The results obtained by strain-gauge showed no statistical difference (p = 0.879) between the CMN (645.3 ± 309.2 µÎµ) and MP (639.3 ± 278.8 µÎµ) and allowed the validation of computational models with a difference of 6.3 and 6.4% for the microstrains in the CMN and MC groups, respectively. Similarly, the results presented by the computational models showed no statistical difference (p = 0.932) for the CMN (605.1 ± 358.6 µÎµ) and MC (598.7 ± 357.9 µÎµ) groups. The study concluded that strain-gauge is an effective method for the validation of computational models and that the use of CMN or MC abutments to support a fixed partial denture cab be indicated without causing a deleterious strain magnitude (3,000 µÎµ) regardless the loading region.


Assuntos
Implantes Dentários , Prótese Dentária , Materiais Dentários
15.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385693

RESUMO

ABSTRACT: The aim of this study was to identify the incidence of fractures in single crowns placed in individuals with chronic tooth wear. The sample selection was performed based on the evaluation of 218 patient records rehabilitated with single crowns placed by the same professional from a private clinic. After exclusion criteria, 43 individuals (18 males and 25 females) were included and a total of 112 single crowns distributed in both jaws. Three ceramic systems were evaluated: 34 feldspathic all-ceramic, 38 metal-ceramic with a core in gold electropositive alloy, and 40 In-Ceram Alumina. The intraoral photograph analysis adopted a diagnosis method of tooth wear according to the morphological variations of the teeth. Of the 112 crowns evaluated, 47 were placed in male and 65 in female patients, aged between 21 to 74 years (mean 27.5 years old). The variables gender (p = 0.83), presence of chronic tooth wear (p = 0.91), ceramic system (p = 0.24) and crown location (p = 0.86) did not present a statistically difference. However, the variables pulp vitality (p = 0.04) and survi val time (p = 0.01) presented a statistically significant difference. The evaluated ceramic systems can be considered as alternativ es of restorative material, even in individuals with clinical characteristics suggestive of chronic tooth wear.


RESUMEN: El objetivo de este estudio fue identificar la incidencia de fracturas en coronas individuales colocadas en individuos con desgaste dental crónico. La selección de la muestra se realizó en base a la evaluación de 218 registros de pacientes rehabilitados con coronas individuales colocadas entre 1999 y 2009 por el mismo profesional de una clínica privada. Después de analizar los criterios de exclusión, se incluyeron 43 individuos (18 hombres y 25 mujeres) y un total de 112 coronas individuales distribuidas en ambas mandíbulas. Este estudio evaluó coronas hechas de tres sistemas cerámicos: 34 de cerámica totalmente feldespática, 38 de cerámica de metal con un núcleo de aleación electropositiva de oro y 40 de alúmina enceram. El análisis de la fotografía intraoral adoptó un método de diagnóstico del desgaste dental de acuerdo con las variaciones morfológicas de los dientes. De las 112 coronas evaluadas, 47 se colocaron en hombres y 65 en mujeres, con edades comprendidas entre 21 y 74 años (media de 27,5 años). Con respecto a las coronas individuales, las variables género (p = 0,83), presencia de desgaste dental crónico (p = 0,91), sistema cerámico (p = 0,24) y ubicación de la corona (p = 0,86) no presentaron una diferencia estadísticamente significativa. Sin embargo, las variables vitalidad pulpar (p = 0.04) y tiempo de supervivencia (p = 0.01) presentaron una diferencia estadísticamente significativa. Los sistemas cerámicos evaluados pueden considerarse como alternativas de material restaurador, incluso en individuos con características clínicas que sugieren desgaste dental crónico.

16.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385707

RESUMO

ABSTRACT: This study aims to evaluate the physical, chemical, mechanical and optical properties of Bulk-Fill resin, in relation to the literature and its proper clinical uses. A bibliographic search was performed in the main health databases PUBMED (www.pubmed.gov) and Scholar Google (www.scholar.google.com.br), in which articles published from 1994 to 2020 were collected. Laboratory studies, case reports, systematic reviews and literature reviews, which were developed in living individuals, were included. Therefore, articles that did not deal with the characteristics of the Bulk-Fill resin and its proper clinical uses were excluded. The use of Bulk-Fill resin has been progressively increasing over the years, presenting good properties, achieving success in clinical performance, ease of handling and thus has become the material of choice for dentists. In addition, its longevity demonstrates durability with mechanical properties and resistance to tooth structure. Bulk - Fill resins have characteristics similar to traditional composite resins, when performed according the usage protocol. With the use of this group of resins in a single increment, possible failures that occur during the restorative procedure can be minimized, such as: less chance of incorporating bubbles and a volumetric contraction with less stress on the interface.


RESUMEN: Este estudio tuvo como objetivo evaluar las propiedades físicas, químicas, mecánicas y ópticas de la resina Bulk-Fill, en relación con la literatura y sus usos clínicos apropiados. Realizamos una búsqueda bibliográfica en las bases de datos de salud PUBMED (www.pubmed.gov) y Scholar Google (www.scholar.google.com.br), en la que se recopilaron trabajos que se publicaron entre 1994 y 2020. Fueron incluidos estudios de laboratorio, informes de casos, revisiones sistemáticas y revisiones de literatura, desarrollados en individuos vivos. Por tanto, se excluyeron los artículos que no trataban las características de la resina Bulk-Fill y sus usos clínicos adecuados. El uso de la resina Bulk-Fill ha ido aumentando progresivamente a lo largo de los años, presentando buenas propiedades, logrando éxito en el rendimiento clínico, facilidad de manejo y, por lo tanto, se ha convertido en el material elegido por los dentistas. Además, su longevidad demuestra durabilidad, con propiedades mecánicas y resistencia a la estructura dental.Las resinas Bulk-Fill tienen características similares a las resinas compuestas tradicionales, cuando se realizan siguiendo el protocolo de uso. Con el uso de este grupo de resinas mono incremental, es posible eliminar el paso de varios incrementos, disminuyendo a su vez el tiempo clínico. Además, se pueden minimizar las posibles fallas que se producen durante el procedimiento de restauración, tales como: menos posibilidades de incorporar burbujas y una contracción volumétrica con menos estrés en la interfaz.

17.
Int. j. odontostomatol. (Print) ; 14(4): 678-684, dic. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1134557

RESUMO

ABSTRACT: The present study aims to describe, through a case report, the functioning of bone grafts, where they are obtained including bone banks and the different dental areas in which it is used. A 50-year.old female patient HMR, sought the postgraduate college of dentistry CECAPE for oral rehabilitation. The initial clinical examination revealed the absence of several dental elements in both the maxilla and mandi ble, bone resorption in the entire maxillary extension where there was an absence of elements in the anterior region and the presence of a torus in the palatal region. Initial tomographic examinations of the maxilla and mandible were performed, looking for the best conduct regarding the diagnosis and planning of the case. After the clinical and radiographic examinations was performed, and the diagnosis was reached, it was determined as a treatment for oral rehabilitation of the maxilla, bone grafting and an Implant-supported Removable Partial Prosthesis and for the mandible a Dento-muco-supported Removable Partial Prosthesis. Dental treatments and oral rehabilitation from the use of bone tissues and bone grafting have become commonly used. Procedures that would normally lead to failure started to increase the percentage of successes due to the use of these biomaterials. The use of bone grafts in dentistry has been shown to be a very effective and useful resource, considering its great applicability in bone reconstructions in different areas of dentistry.


RESUMEN: El presente estudio tiene como objetivo describir a través de un informe de caso, el funcionamiento de los injertos óseos, donde se obtienen, incluidos los bancos de huesos y las diferentes áreas dentales en las que se emplea. Una paciente HMR, de 50 años de edad, asistió el centro universitario de posgrado CECAPE para rehabilitación oral. El examen clínico inicial reveló la ausencia de varios dientes tanto en el maxilar como en la mandíbula, la resorción ósea en toda la extensión maxilar donde había ausencia de dientes en la región anterior y la presencia de un torus en la región palatina. Se realizaron exámenes tomográficos iniciales del maxilar y mandíbula, buscando la mejor conducta con respecto al diagnóstico y la planificación del caso. Después de los exámenes clínicos y radiográficos realizados y el diagnóstico listo, se determinó como un tratamiento para la rehabilitación oral del maxilar, el injerto óseo y una prótesis removible implantosoportada y para la mandíbula una prótesis parcial removible dento-muco-soportada. Los tratamientos dentales y la rehabilitación oral a partir del uso de tejidos óseos y el injerto óseo se han utilizado comúnmente. Los procedimientos que normalmente conducirían al fracaso comenzaron a aumentar el porcentaje de éxitos debido al uso de estos biomateriales. Se ha demostrado que el uso de injertos óseos en odontología es un recurso muy eficaz y útil, considerando su gran aplicabilidad en las reconstrucciones óseas en diferentes áreas de la odontología.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Transplante Ósseo/métodos , Implantação Dentária Endóssea/métodos , Interface Osso-Implante/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Mandíbula/diagnóstico por imagem , Reabilitação Bucal
18.
Int. j. odontostomatol. (Print) ; 14(3): 457-463, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1114921

RESUMO

To evaluate clinically the results of two surgical techniques used for root coverage, the coronally advanced flap in '' L '' isolated (CAF) or associated with subepithelial connective tissue graft (SCTG). The surgical procedures were performed in seventeen individuals, ten individuals in the control group (coronally advanced flap in "L") and seven individuals in the test group (coronally advanced flap in "L" associated with SCTG), who presented Miller class I and II gingival recession. The depth gingival recession (GR) index was evaluated in the following periods: immediate preoperative and 180 postoperative days. The control group had a success rate of 85 +/- 18 % and the test group had a success rate of 95 +/- 4 %. The variable success rates (p=0.36) did not present a statistically significant difference. The isolated CAF or its association with SCTG showed favorable outcomes in the treatments of Miller's class I and II gingival recessions.


El objetivo fue evaluar clínicamente los resultados de dos técnicas quirúrgicas utilizadas para la cobertura radicular, el colgajo coronalmente avanzado en "L" aislado (CAF) o asociado con injerto de tejido conectivo subepitelial (SCTG). Los procedimientos quirúrgicos se realizaron en diecisiete individuos, diez individuos en el grupo de control (colgajo coronario avanzado en "L") y siete individuos en el grupo de prueba (colgajo coronalmente avanzado en "L" asociado con SCTG), que presentaron la clase I de Miller y II recesión gingival. El índice de recesión gingival profunda (RG) se evaluó en los siguientes períodos: preoperatorio inmediato y 180 días postoperatorios. El grupo de control tuvo una tasa de éxito de 85 +/- 18 % y el grupo de prueba tuvo una tasa de éxito de 95 +/- 4 %. Las tasas de éxito variables (p = 0,36) no presentaron una diferencia estadísticamente significativa. La CAF aislada o su asociación con SCTG mostraron resultados favorables en los tratamientos de las recesiones gingivales de clase I y II de Miller.


Assuntos
Humanos , Retalhos Cirúrgicos , Tecido Conjuntivo/transplante , Retração Gengival/cirurgia , Raiz Dentária , Estudos de Casos e Controles , Resultado do Tratamento
19.
J Indian Prosthodont Soc ; 19(4): 283-289, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31649436

RESUMO

AIMS: The aim of the study is to evaluate the profile of peri-implant tissues in periodontally compromised patients. SETTINGS AND DESIGN: In vivo - cross sectional study design. MATERIALS AND METHODS: Fifty-eight implants were evaluated, clinically and radiographically, installed in seven individuals treated by the same team of professionals, during the years 1997 and 2005 in a private dental clinic in Vitória, ES, Brazil; that time of data collection, all implants were at least 10 years of functional loading. The variables related to the dental implants evaluated were: visible Plaque Index, Gingival Bleeding Index (GBI), probing pocket depth, bleeding on probing, and bone level, to relate them to the classification of dental implants. STATISTICAL ANALYSIS USED: The Chi-square and Kruskal-Wallis test were adopted. RESULTS: The total of 58 implants were classified: 11 (18.9%) as healthy and 12 (20.7%) as clinically stable. The other 35 implants (60.4%) had some type of peri-implant inflammation, 20 of them (34.5%) were diagnosed with peri-implant mucositis and 15 (25.9%) with peri-implantitis. Among the variables studied, the results showed statistically significant differences for implant location (P = 0.001) and GBI (P = 0.03). Most of the maxillary implants (85.7%) were classified for some type of peri-implant disease. For the implants which resulted in Score 1 for GBI, most of them (75.0%) were also classified for some type of peri-implant disease. CONCLUSIONS: Dental implants placed in periodontally compromised patients may have high long-term survival rates. However, most implants were classified with some type of peri-implant inflammation.

20.
Int. j. odontostomatol. (Print) ; 12(4): 368-375, dic. 2018. graf
Artigo em Inglês | LILACS | ID: biblio-975759

RESUMO

ABSTRACT: The aim of this study was to carry out a literature review on the accuracy of conventional and digital dental impression methods, as well as present the various three-dimensional intraoral scanning systems. A bibliographic search was carried out in PUBMED's main health database, in which works published between 2008 and 2018 were collected. Laboratory studies, case reports and systematic reviews were included, addressing topics that deal with conventional digital materials, impression and precision. Articles that did not evaluate impression materials, their behavior and techniques to obtain a good impression of oral structures were excluded. Through a review in the literature, obtained the following findings: the most critical stage in macking a dental prothesis is to take the dental impression. The conventional technique of impression consists of obtaining a negative copy of the intra-oral situation that will be poured into gypsum, obtaining a positive copy, on which the work will be carried out. Digital scanning systems were not superior to conventional moldings when comparing fidelity, accuracy and detail reproduction; in contrast, they were superior to conventional impression when considering clinical chair time, patient and operator preference, and patient comfort.


RESUMEN: El objetivo de este estudio consistió en realizar una revisión bibliográfica sobre la precisión de los métodos de moldeo dental convencionales y digitales, así como presentar los diversos sistemas de escaneo intraoral tridimensionales. Se realizó una búsqueda bibliográfica en la base de datos de salud principal de PUBMED en la cual se recopilaron trabajos publicados entre 2008 y 2018. Se incluyeron estudios de laboratorio, informes de casos y revisiones sistemáticas, abordando temas que tratan con materiales digitales convencionales, moldeo y precisión. Se excluyeron los artículos que no evaluaron los materiales de moldeo, su comportamiento y técnicas para obtener una buena impresión de las estructuras orales. A través de una revisión exhaustiva en la literatura, obtuvimos los siguientes hallazgos: el paso más crítico en la preparación de una pieza protésica es la impresión de la preparación. La técnica convencional de moldeo consiste en obtener una copia negativa de la situación intraoral que se verterá en el yeso, obteniendo una copia positiva, sobre la cual se realizará el trabajo. Resulta que los sistemas de escaneo digital no fueron superiores a las molduras convencionales al comparar la fidelidad, precisión y reproducción de detalles; en cambio, fueron superiores a las molduras convencionales al considerar el tiempo de trabajo clínico, la preferencia del paciente y del operador y la comodidad del paciente.


Assuntos
Humanos , Técnica de Moldagem Odontológica/classificação , Técnica de Moldagem Odontológica/instrumentação , Materiais para Moldagem Odontológica/química , Planejamento de Prótese Dentária , Impressão Tridimensional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...